Lightweight Enclosure cooling unit (HFC alternative)

  1. HOME
  2. Enclosure Cooling Unit ENC Series
  3. Model list
  4. ENC-ER1000L-MT
Lightweight Enclosure Cooling Unit Enclosure Cooling Unit (HFC alternative) ENC-ER1000L-MT

Lightweight Enclosure Cooling Unit (HFC alternative)
ENC-ER1000L-MT

Cooling capacity(W)*1 850/1000
Rated voltage(V) Single-phase 200 to 240V AC
Mounting Type Side-mounting
External Dimensions(mm) H730×W350×D198
Weight(kg) 約20

ENC-ER1000L-MT Product details

(50/60Hz)

Mounting Type Side-mounting
cooling capacity (W) * 850/1000
Setting temperature range (℃) 25~45
Use Area Temperature (°C) * 20 to 50
use area Humidity (%RH) * 10~85 (No condensation)
External Dimensions(mm) H730×W350×D198
Weight(kg) 約20
Coating Color Munsell 5Y7/1 light beige equivalent
Rated voltage(V) Single-phase 200 to 240V AC
current consumption: rating (A) * 1.9/2.4
Starting current (A) 14.7/14.2
power consumption: rating (W) * 375/416
Recommended breaker capacity (A) 10
Vibration resistance JIS Z0200 Level 1
Dustproof and splashproof protection rating * Equivalent to IP54 (internal circulation route)
Certification
refrigerant types R1234yf
refrigerant filling amount (g) 230
Noise (dB(A)) 約66/69
External output alarm output (No-voltage a-contact: AC250V 2A/DC30V 2A resistive load)
Display Panel temperature/Error/RUN

1 rating capacity values at an ambient temperature of 35°C, humidity of 40%RH, and power-supply voltage 200V.
(Test method: indoor side air enthalpy test method based on JIS B 8615-1)
2 Use Area Temperature / use area Humidity define the operating range and do not guarantee rating performance.
3 rating values at ambient temperature 35°C, humidity 40%RH, power-supply voltage 200V.
4 Excluding the drain port.

External dimensions

ENC-ER1000L-MT Outline Dimensions Diagram

Diagram of Panel Cutout

ENC-ER1000L-MT Installation Diagram

cooling capacity characteristic diagram

ENC-ER1000L-MT cooling capacity Characteristic Diagram

*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.

【Note】
Please read the instruction manual before use and use the product correctly.
◯Products will be delivered to the vehicle (at designated locations within Japan, excluding remote islands).
Depending on model and number of units, a separate charter service (additional fees apply) may be required.
◯For overseas deliveries, we recommend using separate overseas packaging.
Please check specification of Enclosure Cooling Unit and install an appropriate circuit breaker (wiring breaker) between Enclosure Cooling Unit and power supply.
Using the device outside of rating power supply range may cause malfunctions.
Please perform regular maintenance.
Neglecting regular maintenance can lead to product performance degradation and malfunctions.
◯During winter when outside temperatures are low, do not operate Enclosure Cooling Unit continuously.
When disposal of this product, please do so in accordance with all applicable laws and regulations.

If you are having trouble selecting a product or would like to discuss implementation,
please feel free to contact us.

Inquiry

For product inquiries, quote requests, etc.
Please feel free to contact us.

TEL: 0120-945-354

This service is not available from some IP phones.

support@apiste.co.jp