Lightweight Enclosure Cooling Unit (HFC alternative)
ENC-ER1000L-MT
| Cooling capacity(W)*1 | 850/1000 |
|---|---|
| Rated voltage(V) | Single-phase 200 to 240V AC |
| Mounting Type | Side-mounting |
| External Dimensions(mm) | H730×W350×D198 |
| Weight(kg) | 約20 |
Inquiry
Download
ENC-ER1000L-MT Product details
Specifications
See specification in the catalogue(50/60Hz)
| Mounting Type | Side-mounting |
|---|---|
| cooling capacity (W) * | 850/1000 |
| Setting temperature range (℃) | 25~45 |
| Use Area Temperature (°C) * | 20 to 50 |
| use area Humidity (%RH) * | 10~85 (No condensation) |
| External Dimensions(mm) | H730×W350×D198 |
| Weight(kg) | 約20 |
| Coating Color | Munsell 5Y7/1 light beige equivalent |
| Rated voltage(V) | Single-phase 200 to 240V AC |
| current consumption: rating (A) * | 1.9/2.4 |
| Starting current (A) | 14.7/14.2 |
| power consumption: rating (W) * | 375/416 |
| Recommended breaker capacity (A) | 10 |
| Vibration resistance | JIS Z0200 Level 1 |
| Dustproof and splashproof protection rating * | Equivalent to IP54 (internal circulation route) |
| Certification | |
| refrigerant types | R1234yf |
| refrigerant filling amount (g) | 230 |
| Noise (dB(A)) | 約66/69 |
| External output | alarm output (No-voltage a-contact: AC250V 2A/DC30V 2A resistive load) |
| Display | Panel temperature/Error/RUN |
1 rating capacity values at an ambient temperature of 35°C, humidity of 40%RH, and power-supply voltage 200V.
(Test method: indoor side air enthalpy test method based on JIS B 8615-1)
2 Use Area Temperature / use area Humidity define the operating range and do not guarantee rating performance.
3 rating values at ambient temperature 35°C, humidity 40%RH, power-supply voltage 200V.
4 Excluding the drain port.
External dimensions

Diagram of Panel Cutout

cooling capacity characteristic diagram

*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.
【Note】
Please read the instruction manual before use and use the product correctly.
◯Products will be delivered to the vehicle (at designated locations within Japan, excluding remote islands).
Depending on model and number of units, a separate charter service (additional fees apply) may be required.
◯For overseas deliveries, we recommend using separate overseas packaging.
Please check specification of Enclosure Cooling Unit and install an appropriate circuit breaker (wiring breaker) between Enclosure Cooling Unit and power supply.
Using the device outside of rating power supply range may cause malfunctions.
Please perform regular maintenance.
Neglecting regular maintenance can lead to product performance degradation and malfunctions.
◯During winter when outside temperatures are low, do not operate Enclosure Cooling Unit continuously.
When disposal of this product, please do so in accordance with all applicable laws and regulations.
If you are having trouble selecting a product or would like to discuss implementation,
please feel free to contact us.
People who viewed this page also checked out these documents:
Inquiry
For product inquiries, quote requests, etc.
Please feel free to contact us.